Laser Distance, Level and Speed Meter LD90-3 |
![]() |
The sensors of series LD90-3 are based upon the well-proved principle of time-of-flight measurement of short laser pulses, like all RIEGL products. They can be operated with practically any target surface, i.e. "reflectorless" up to many hundred meters, and with reflecting foil or retroreflectors up to more than 1000 m. |
|
General
purpose distance meter |
|
| An electrical pulse generator periodically drives a semiconductor laser diode sending out infrared light pulses, which are collimated and emitted by the transmitter lens. Via the receiver lens, part of the echo signal reflected by the target hits a photodiode which generates an electrical receiver signal. | The time interval between the transmitted and received pulses is counted by means of a quartz-stabilised clock frequency. The result is fed into the internal microcomputer which processes the measured data and prepares it for the various data outputs. |

Available instrument types
General purpose distance meter
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
Available Data Interfaces | ||
| LD90-3100HS |
150 m |
> 1000 m |
± 15 mm |
1 ¸ 200 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
High-Range ship docking sensor, Laser altimeter
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
Available Data Interfaces | ||
| LD90-3300 |
400 m |
> 1000 m |
± 50 mm |
0.5 ¸ 100 Hz |
RS232 & RS422 | 4-20 mA current output (optional) | 2xPNP switching output (optional) |
| LD90-3300HR |
500 m |
> 1000 m |
± 50 mm |
0.5 ¸ 100 Hz |
RS232 & RS422 | 4-20 mA current output (optional) | 2xPNP switching output (optional) |
| 1500 m | 2500 m | ± 50 mm | 0.5 ¸ 3 Hz | RS232 & RS422 | 4-20 mA current output (optional) | 2xPNP switching output (optional) | |
Very High-Speed distance meter
|
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate |
Available Data Interfaces | ||
| LD90-3100VHS-FLP |
200 m |
350 m | ± 25 mm | 2000 Hz |
RS232 & RS422 |
RS422 high speed |
| LD90-3300VHS-FLP |
400 m |
700 m | ± 50 mm | 2000 Hz |
RS232 & RS422 |
RS422 high speed |
Distance Sensor for Explosion-Endangered Areas
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3200HiP-ATEX |
250 m |
- |
± 25 mm |
0.5 / 3Hz |
RS232 & RS422 | 4-20 mA | 2xPNP switching output |
| LD90-3200HiP-ATEX "GAS ONLY" |
250 m |
- |
± 25 mm |
0.5 / 3Hz |
RS232 & RS422 | 4-20 mA | 2xPNP switching output |
Extremely High-Speed scanner applications
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate |
available data interfaces | |
| LD90-3100EHS-FLP |
200 m |
350 m |
± 25 mm |
12 000 Hz |
RS232 & RS422 | ECP |
| LD90-3300EHS-FLP |
400 m |
700 m |
± 50 mm |
12 000 Hz |
RS232 & RS422 | ECP |
"High Penetration" level meter
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3200HiP |
400 m |
2000 m |
± 25 mm |
0.5 ¸ 3 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3800VHS-FLP | 750 m | 1000 m | ± 50 mm | 2000 Hz | RS232 & RS422 | RS422 high speed | - |
| LD90-3800EHS-FLP | 750 m | 1000 m | ± 50 mm | 12 000 Hz | RS232 & RS422 | - | ECP |
Distance sensor for High-Temperature targets
| Instrument type |
Range reflectorless |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | |||
| LD90-3100HS-HT | 3 - 7 m (at 1450°C) | ± 15 mm | 1 ¸ 20 Hz | RS232
& RS422 |
4-20 mA (optional) | 0-10V voltage output (optional) | 2xPNP switching output (optional) |
Information contained herein is believed to be accurate and reliable. However, no responsibility is assumed by RIEGL for its use. Technical data are subject to change without notice.
Last updated 08/22/06