Back to Distance & Level Sensors Next RIEGL Product

Back to Home Page

Laser Distance, Level and Speed Meter
LD90-3GF with Glass-Fiber coupled remote optical head

 

  • Distance and level measurements in explosion-endangered areas
  • Level measurement of liquid steel in melting pots or in transfer ladles
  • Robotic applications in nuclear power plants
  • Measurement of the position, width, and thickness or glowing slabs in rolling mills
  • Sensor for ship docking systems
  • Laser altimeter
  • Crane coordinate measurement
General
Principle of operation
Optical heads
Scope of delivery & Accessories

Available instrument types:

General purpose distance meter
Long-range ship docking meter
Very-High Speed distance meter
Extremely High-Speed meter for scanner applications
"High Penetration" level meter
Distance meter for High-Temperature targets


General

The distance and level meter LD90-3-GF with glass-fiber coupled optical head makes use of the time-of-flight method to determine the distance of a remote target by measuring the transit-time between transmission and reception of a short laser pulse.

Distance measurements can be performed to both non-cooperative and cooperative targets with high accuracy, interference immunity, and excellent reliability. The serial interface allows communication and operation of the instrument. Furthermore, the LD90-3-GF can be equipped with the various digital and analog data outputs frequently used in industry.

The measuring system consists of a lightweight and small optical head and a separate electronics box, connected by a duplex glass-fiber cable with connectors on both sides. Its length can be choosen between 10 m and up to more than 100 m.

The main features and advantages of this flexible and powerful configuration are:
  • The LD90-3-GF electronics unit can be combined with various optical heads to suit nearly any requirement.
  • The optical head contains no electronics and is therefore extremely small, lightweight, inexpensive, high-temperature resistant, and insensitive against electromagnetic or ionizing radiation.
  • The optical head can be operated in explosion-endangered areas as well as in high-temperature areas, whereas the electronics box can be remotely installed in a protected area.
  • The glass-fiber cable provides galvanic insulation between optical head and electronics box.
  • Installation as well as replacement of parts of the system in case of servicing requirements is easy and cost-effective.

Principle of operation


Optical heads

The LD90-3GF electronics can be combined with various optical heads to suit nearly any requirement:

General purpose distance sensing

     - short distances

 

MK36

 

very small & lightweight

 

120 x 80 x 50 mm

     - medium distances MK42 small & lightweight, lenses can be equipped with filters 86 x 100 x 60 mm

Long range ship docking sensor MK56-Z150 splash-water proof cylindrically shaped, total length 460 mm x diameter 150 mm
MK75-Z210 water-proof, stainless steel case for highest resistance against sea-water cylindrically shaped, total length 600 mm x diameter 210 mm

Measurement through boreholes MK42-Z80 water proof, side-looking cylindrically shaped, length 370 mm x diameter 80 mm

High-temperature targets MK36-HT with heat protecting filters completely water-cooled, with mounting flange cylindrically shaped, total length 650 mm x diameter 130 mm
MK56-HT with heat protecting filters total 550 x 120 x 70 mm

Available instrument types

General purpose distance meter

Instrument type           

Range reflectorless

Range with retroreflector

Accuracy, typically

Update rate (selectable)

available data interfaces
LD90-3100HS-GF equipped with
MK36

100 m

> 1000 m

± 15 mm

1 ¸ 200 Hz

RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)
LD90-3100HA-GF equipped with
MK36
100 m > 1000 m ± 10 mm 0.5 ¸ 100 Hz RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)

Long-range ship docking sensor, Laser altimeter

Instrument type           

Range reflectorless

Range with retroreflector

Accuracy, typically

Update rate (selectable)

available data interfaces
LD90-3300-GF equipped with
MK42(-Z80)

300 m

>1000 m

± 50 mm

0.5 ¸ 100 Hz

RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)
LD90-3300-GF equipped with
MK56-Z150

400 m

>1000 m

± 50 mm

0.5 ¸ 100 Hz

RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)
LD90-3300-GF equipped with
MK75-Z210
500 m >1000 m ± 50 mm 0.5 ¸100 Hz RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)

Very High-Speed distance meter

Instrument type           

Range reflectorless

Range with retroreflector

Accuracy, typically

Update rate

available data interfaces
LD90-3100VHS-FLP-GF
equipped with
MK36

150 m

700 m

± 25 mm

2000 Hz

RS232 & RS422

RS422 high speed

Extremely High-Speed scanner applications

Instrument type           

Range reflectorless

Range with retroreflector

Accuracy, typically

Update rate

available data interfaces
LD90-3100EHS-FLP-GF
equipped with
MK36

150 m

350 m

± 25 mm

12 000 Hz

RS232 & RS422 ECP
LD90-3300EHS-FLP-GF
equipped with
MK42

300 m

700 m

± 50 mm

12 000 Hz

RS232 & RS422 ECP

"High Penetration" level meter

Instrument type           

Range reflectorless

Range with retroreflector

Accuracy, typically

Update rate (selectable)

available data interfaces
LD90-3200HiP-GF equipped with
MK42

600 m

2000 m

± 25 mm

0.5 ¸ 3 Hz

RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)

Distance sensor for High-Temperature targets

Instrument type           

Range reflectorless

Accuracy, typically

Update rate (selectable)

available data interfaces
LD90-310HT-GF equipped with
MK36(-HT)
3 - 7 m (at 1450°C) ± 10 mm 0.5 ¸ 10 Hz RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)
LD90-3100HT-GF equipped with
MK56-HT
3 - 10 m (at 1650 °C) ± 15 mm 0.5 ¸ 10 Hz RS232 & RS422 4-20 mA (optional) 2xPNP switching output (optional)