Laser Distance, Level and Speed Meter
|
![]() |
|
| General Principle of operation Optical heads Scope of delivery & Accessories |
|
| Available instrument
types: General purpose
distance meter |
|
| The distance and level
meter LD90-3-GF with glass-fiber coupled optical head makes use of the
time-of-flight method to determine the distance of a remote target by
measuring the transit-time between transmission and reception of a short
laser pulse.
Distance measurements can be performed to both non-cooperative and cooperative targets with high accuracy, interference immunity, and excellent reliability. The serial interface allows communication and operation of the instrument. Furthermore, the LD90-3-GF can be equipped with the various digital and analog data outputs frequently used in industry. The measuring system consists of a lightweight and small optical head and a separate electronics box, connected by a duplex glass-fiber cable with connectors on both sides. Its length can be choosen between 10 m and up to more than 100 m. |
The main features and
advantages of this flexible and powerful configuration are:
|

The LD90-3GF electronics can be combined with various optical heads to suit nearly any requirement:
| General purpose distance
sensing
- short distances |
very small & lightweight |
120 x 80 x 50 mm |
|
| - medium distances | MK42 | small & lightweight, lenses can be equipped with filters | 86 x 100 x 60 mm |
|
|
|||
| Long range ship docking sensor | MK56-Z150 | splash-water proof | cylindrically shaped, total length 460 mm x diameter 150 mm |
| MK75-Z210 | water-proof, stainless steel case for highest resistance against sea-water | cylindrically shaped, total length 600 mm x diameter 210 mm | |
|
|
|||
| Measurement through boreholes | MK42-Z80 | water proof, side-looking | cylindrically shaped, length 370 mm x diameter 80 mm |
|
|
|||
| High-temperature targets | MK36-HT | with heat protecting filters completely water-cooled, with mounting flange | cylindrically shaped, total length 650 mm x diameter 130 mm |
| MK56-HT | with heat protecting filters | total 550 x 120 x 70 mm | |
Available instrument types
General purpose distance meter
| Instrument type | Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3100HS-GF equipped with MK36 |
100 m |
> 1000 m |
± 15 mm |
1 ¸ 200 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
| LD90-3100HA-GF equipped with MK36 |
100 m | > 1000 m | ± 10 mm | 0.5 ¸ 100 Hz | RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
Long-range ship docking sensor, Laser altimeter
| Instrument type | Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3300-GF equipped with MK42(-Z80) |
300 m |
>1000 m |
± 50 mm |
0.5 ¸ 100 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
| LD90-3300-GF equipped with MK56-Z150 |
400 m |
>1000 m |
± 50 mm |
0.5 ¸ 100 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
| LD90-3300-GF
equipped with MK75-Z210 |
500 m | >1000 m | ± 50 mm | 0.5 ¸100 Hz | RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
Very High-Speed distance meter
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate |
available data interfaces | |
| LD90-3100VHS-FLP-GF
equipped with MK36 |
150 m |
700 m |
± 25 mm |
2000 Hz |
RS232 & RS422 |
RS422 high speed |
Extremely High-Speed scanner applications
| Instrument type |
Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate |
available data interfaces | |
| LD90-3100EHS-FLP-GF
equipped with MK36 |
150 m |
350 m |
± 25 mm |
12 000 Hz |
RS232 & RS422 | ECP |
| LD90-3300EHS-FLP-GF
equipped with MK42 |
300 m |
700 m |
± 50 mm |
12 000 Hz |
RS232 & RS422 | ECP |
"High Penetration" level meter
| Instrument type | Range reflectorless |
Range with retroreflector |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-3200HiP-GF equipped with MK42 |
600 m |
2000 m |
± 25 mm |
0.5 ¸ 3 Hz |
RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
Distance sensor for High-Temperature targets
| Instrument type | Range reflectorless |
Accuracy, typically |
Update rate (selectable) |
available data interfaces | ||
| LD90-310HT-GF equipped with MK36(-HT) |
3 - 7 m (at 1450°C) | ± 10 mm | 0.5 ¸ 10 Hz | RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
| LD90-3100HT-GF equipped with MK56-HT |
3 - 10 m (at 1650 °C) | ± 15 mm | 0.5 ¸ 10 Hz | RS232 & RS422 | 4-20 mA (optional) | 2xPNP switching output (optional) |
Information contained herein is believed to be accurate and reliable. However, no responsibility is assumed by RIEGL for its use. Technical data are subject to change without notice.
Last updated 07/20/05