contact Riegl USA

VQ - 180

Technical Data

Performance:
Eye safety class according to:
-IEC60825-1:1993+A1:1997+A2:2001

The following clause applies for instruments delivered into the United States:
-Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Measuring principle
time-of-flight measurement
  echo signal digitization
  online waveform analysis
Laser Pulse Repetition Rate PRR 1) 1m
Minimum range 1m
Minimum range 1m
Minimum range 1m
Accuracy 15mm
Precision 2) 10mm
Laser Pulse Repetition Rate up to 200 kHz
Effective Measurement Rate up to 83,000 meas./s
(@ 200 kHz PRR & 100° field of view)
Laser wavelength near infrared
Laser Beam Divergence 3) 0.3 mrad
Echo Signal Intensity for each echo signal, high-
resolution 16 bit intensity information is provided.
Laser Beam Footprint
(Gaussian beam definition)
31mm @ 100m
50mm @ 150m
Scanner Performance:
Scanning Mechanism rotating multi-facet mirror
Field-of-view (max.) 100° (+60° / -40°)
Scanning rate (selectable) 10 - 100 scans/s
Angle Step Width ∆ (selectable)
between consecutive laser shots
0.012° ≤ ∆ ≤ 0.48°
Angular measurement resolution 0.001°
Internal Sync Timer for GPS-synchronized time stamping of scan data
Scan Sync for synchronizing scan lines to an external timing signal
Data Interfaces:
for GPS-system Serial RS232 Interface for data string with GPS-time information, TTL input for 1 PPS synchronization pulse.
for Configuration LAN 10/100/1000 Mbit/s
for Data Output LAN 10/100/1000 Mbit/s
General Techical Data:
Power supply Input voltage 11 - 32 V DC
Power Consumption typ. 50 W
Main Dimensions (diameter x length) 180 x 295 mm (without mounting brackets)
Weight 9.0 kg
   
Environmental data  
Temperature Storage -20°C to +50°C /
Temperature Operation -10°C to + 40°C
Protection class IP64, dust and splash-proof

Footnotes:
1) Rounded Values
2) The following conditions are assumed: target larger than the footprint of the laser beam, perpendicular angle of incidence, visibility 23km, average ambient brightness.
3) Accuracy is the degree of conformity of a measured quantity to its actual (true) value.
4) Precision, also called reproducibility, or repeatability, is the degree to which further measurements show the same result.
5) One sigma @ 150 m range under RIEGL test conditions

Main Applications

Topography & Mining
City Modeling
Mapping of Coastal Lines
Power Lines
Civil Engineering

 

Get the Specs

View the technical specifications for this product by clicking the link below:

VQ-180 Technical Specifications »